3: Operating the Projector
CHRISTIE INC. CHRISTIE INC. - - 35/70 Service/PM Manual
July, 1997
Input Comment Result
G9
Must be entered from console. Activates the serial RS-232
communications port (see Section 0).
M xxxx
“M” followed by desired
hexadecimal memory location (use
upper case for alpha characters).
Data stored at the chosen address is
shown to the right of that address on
the terminal’s display.
yy
New value for memory location (two
hex digits).
Value at selected address is updated.
Up-arrow cursor. Increment memory location.
Down-arrow cursor. Decrement memory location.
<ENTER> Exit MEMORY INSPECT.
Table 2.7: MEMORY INSPECT from a Service Terminal.
G1: The DISPLAY FRAME COUNTER Command [DX]
This diagnostic command causes the current frame counter value to be displayed on the LED strip.
ENTRY:
<CMD-G>, <1>
CODE:
G1
ACTION
S:
Display the current frame counter value.
STATUS:
Unchanged.